{"id":5898,"date":"2025-05-04T07:09:26","date_gmt":"2025-05-04T07:09:26","guid":{"rendered":"https:\/\/germanymedical.au\/plastic-surgery\/?page_id=5898"},"modified":"2025-05-04T07:18:12","modified_gmt":"2025-05-04T07:18:12","slug":"sterilizing-cleaning-instructions","status":"publish","type":"page","link":"https:\/\/germanymedical.au\/plastic-surgery\/sterilizing-cleaning-instructions\/","title":{"rendered":"Sterilizing &amp; Cleaning Instructions"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"5898\" class=\"elementor elementor-5898\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f9d905a e-flex e-con-boxed e-con e-parent\" data-id=\"f9d905a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d3f0a1c elementor-widget elementor-widget-text-editor\" data-id=\"d3f0a1c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"my-5 md:my-8\"><h3 class=\"font-Pt-sans-bold text-[22px] md:text-[28px] leading-8 text-[#292D32] mb-1\">Instructions For Use<\/h3><p class=\"text-base\">Dear Customer, we kindly ask you to carefully read the following instructions before handling and using the instruments. Each Germany International Medical instruments has been realized with great care and professionalism and its use is addressed only to qualified and specialised dental personnel.<\/p><\/div><div class=\"my-5 md:my-8\"><h3 class=\"font-Pt-sans-bold text-[22px] md:text-[28px] leading-8 text-[#292D32] mb-1\">1- First Time Use (Initial Use)<\/h3><p class=\"text-base\">Instrument is supplied NON-STERILIZED: it must be properly washed, rinsed and sterilized before use. Many joint instruments present oily residuals in the parts due to the manufacturing processes, please make sure to clean the instruments in a proper way. If the use of a washing-machine is not possible, the instruments can also be washed manually. Use a rigid brush with plastic bristles (No metal bristles) and always make sure the proper washing with decontamination solutions.<\/p><\/div><div class=\"my-5 md:my-8\"><h3 class=\"font-Pt-sans-bold text-[22px] md:text-[28px] leading-8 text-[#292D32] mb-1\">2- Sterilization<\/h3><p class=\"text-base\">It is highly recommended to sterilize the instruments only after proper cleaning. If the instrument is not perfectly cleaned, the result of the sterilization will be prejudiced. Carefully follow the instructions for use provided by the manufacturer of the sterilization equipment. There are different ways for sterilizing the instruments:<\/p><\/div><div class=\"my-5 md:my-8\"><h3 class=\"font-Pt-sans-bold text-[22px] md:text-[28px] leading-8 text-[#292D32] mb-1\">2.1 Autoclave Sterilization<\/h3><p class=\"text-base\">The main aim of the autoclave sterilization is to obtain a proper sterilization and, in the meantime, to maintain the unchanged structural and functional characteristics of the instruments as much as possible. This process must only and exclusively be done by expert personnel, that must have been properly trained for this purpose.<\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>All the cleaning operations must be carried on only in areas duly equipped and organized for this kind of operation.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Immediately after the use, instruments must be disinfected through the use of solutions whose effectiveness has been proved. Make sure of the right dosage of the cleaning\/decontamination solutions, of the washing duration and of its temperature, always follow the Instructions given by the equipment manufacturer and the cleaning solutions\u2019 producer.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Cleaning with disinfectant solutions containing sodium chloride (NaCl) can often cause oxidation or corrosion to the instruments seriously compromising their use and functionality.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Cleaning\/disinfecting solution must be changed daily.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>The best recommended method for a proper washing of the instruments is the ultrasound cleaning, especially suggested for the joint instruments (e.g. pliers, scissors, needle-holders etc.)<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Do not put instruments made of different metals together in the same trays for the washing\/sterilization (e.g. common steel with stainless steel, aluminum, chromed steel etc.)<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Joint instruments (e.g. pliers, scissors, needle-holders) Must be placed in an open position for the washing\/disinfection.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Make sure that trays are not overloaded with instruments because this could compromise the washing\/disinfection.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Possible residuals after the first wash must be completely removed.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>It has been proved that the ideal temperature for the final rinsing is between 80\u00baC and 90\u00baC.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>It is highly recommended to use demineralized water only during the final rinsing. This can avoid the rise up of dark stains.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>To maintain the perfect efficiency of joint instruments. It is necessary to lubricate them regularly with specific products (DO NOT USE INDUSTRIAL OIL AT ALL)<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>In case of instruments with partial carbon fiber handles (Gun Style Intra-ligamental Syringe), please do not autoclave the fiber part. Just remove the stainless-steel part and do that autoclaving for that part.<\/span><\/p><p>Autoclave sterilization through saturated steam is the most used method nowadays; it is based on heat which is necessary to sterilize, on saturated steam, that act on the thermal exchange with the instruments\u2019 temperature, and on the pressure, that increase the water, the water evaporation latent heat.<\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>For this method of sterilization, it is highly recommended to make cycles that do not exceed 7 minutes, with a temperature of 134\u00baC and a pressure of 2.1 bar<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>For the enveloped instruments, it is very important to carefully complete the rinsing cycle because if some water remains into the envelope, it can cause corrosion or oxidation to the instruments resulting in bacteria formation.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>The sterilized instruments must be preserved in defined areas, dry and without dust.<\/span><\/p><\/div><div class=\"my-5 md:my-8\"><h3 class=\"font-Pt-sans-bold text-[22px] md:text-[28px] leading-8 text-[#292D32] mb-1\">Attention: DRY Heat Sterilization<\/h3><p class=\"text-base\">The main aim of the autoclave sterilization is to obtain a proper sterilization and, in the meantime, to maintain the unchanged structural and functional characteristics of the instruments as much as possible. This process must only and exclusively be done by expert personnel, that must have been properly trained for this purpose.<\/p><p class=\"text-base\">A sterilization that exceeds 177\u00baC (350\u00baF), weakens the temper of the instrument and consequently cut the performance and elasticity (above all for the cutting instruments, that can result in decrease of the sharpening): it can also result in darkening of the instruments, brown spots like oxidation.<\/p><\/div><div class=\"my-5 md:my-8\"><h3 class=\"font-Pt-sans-bold text-[22px] md:text-[28px] leading-8 text-[#292D32] mb-1\">3- Aluminum and Titanium Coated Instruments<\/h3><p class=\"text-base\">Do not put aluminum instruments and titanium instruments into thermal equipment and\/or ultrasound bath. For Cleaning of these instruments, only use substances that are specially suggested for aluminum and titanium Instruments.<\/p><\/div><div class=\"my-5 md:my-8\"><h3 class=\"font-Pt-sans-bold text-[22px] md:text-[28px] leading-8 text-[#292D32] mb-1\">4-Germany International Medical Will not be responsible in the following cases:<\/h3><p class=\"text-base\">Do not put aluminum instruments and titanium instruments into thermal equipment and\/or ultrasound bath. For Cleaning of these instruments, only use substances that are specially suggested for aluminum and titanium Instruments.<\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Damages caused by an inappropriate use of the instrument.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Damages caused by a wrong process of cleaning and\/or sterilization of the instruments.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Damages caused by the warehousing of the instruments in unsuitable condition\/s.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Damages caused by the lack of maintaining the instruments.<\/span><\/p><p class=\"text-base\"><span class=\"flex sm:items-center my-4\"><span class=\"mr-2 flex-shrink-0\"><img decoding=\"async\" src=\"https:\/\/densol.com.au\/files\/frontend\/new_images\/svg\/MarkerArrow.svg\" alt=\"\" \/><\/span>Especially for the joint ones, that need a regular lubrication in the joint parts.<\/span><\/p><p class=\"text-base\">For further information or queries. we are at your disposal. Kindly address your requests\/queries to the following address: <a href=\"mailto:info@germanymedical.au\">info@germanymedical.au<\/a><\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Instructions For Use Dear Customer, we kindly ask you to carefully read the following instructions before handling and using the instruments. Each Germany International Medical instruments has been realized with great care and professionalism and its use is addressed only to qualified and specialised dental personnel. 1- First Time Use (Initial Use) Instrument is supplied [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"pagelayer_contact_templates":[],"_pagelayer_content":"","footnotes":""},"class_list":["post-5898","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/germanymedical.au\/plastic-surgery\/wp-json\/wp\/v2\/pages\/5898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/germanymedical.au\/plastic-surgery\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/germanymedical.au\/plastic-surgery\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/germanymedical.au\/plastic-surgery\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/germanymedical.au\/plastic-surgery\/wp-json\/wp\/v2\/comments?post=5898"}],"version-history":[{"count":4,"href":"https:\/\/germanymedical.au\/plastic-surgery\/wp-json\/wp\/v2\/pages\/5898\/revisions"}],"predecessor-version":[{"id":5907,"href":"https:\/\/germanymedical.au\/plastic-surgery\/wp-json\/wp\/v2\/pages\/5898\/revisions\/5907"}],"wp:attachment":[{"href":"https:\/\/germanymedical.au\/plastic-surgery\/wp-json\/wp\/v2\/media?parent=5898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}